Titan Professional | 4000 | 6000 | 8000 | 15000 |
NEW | ||||
Dimensions (l x w x h) (mm) app. | ~ 740 x 410 x 740 | ~ 740 x 410 x 740 | ~ 750 x 460 x 750 | ~ 850 x 550 x 980 |
Net weight (kg) app. | ~ 73 | ~ 68 | ~ 78 | ~ 150 |
Power supply (V) | 220 – 240 ~V / 50 Hz | 380 ~, 3 Ph./50Hz | ||
Cooling capacity (W) app. | 3,800 | 5,200 | 7,200 | 14,900 |
Heating capacity (W) app. | 3,800 | 5,200 | 7,200 | 14,900 |
Compressor power (HP) | 1.5 | 2 | 3 | 5 |
Power uptake cooling (kW) app. | 1.25 | 1.78 | 2.34 | 3.95 |
Power uptake heating (kW) app. | 1.08 | 1.40 | 1.75 | 2.90 |
Rated current consumption (A) app. | 6.5 | 9.8 | 12.5 | 20.8 |
Recommended flow rate (l/h) | 3,000 – 10,000 | 4,000 – 12,000 | 6,500 – 16,000 | 10,000 – 32,000 |
For aquaria up to (l) ΔT = 5 °C | 4,000 | 6,000 | 8,000 | 15,000 |
For aquaria up to (l) ΔT = 10 °C | 2,000 | 3,000 | 4,000 | 7,500 |
Cooling agent and cooling quantity (g) | R410A – 1,180 g | R410A – 1,080 g | R410A – 1,300 g | R410A – 3,100 g |
Heat exchanger | Titan / Titanium | |||
Diameter water in-outlet | 1 1/2“ / 50 mm | |||
Ambient temperature app. | 5 °C – 38 °C | |||
Temperature control range app. | 5 °C – 36 °C | |||
Max. water pressure | ≤ 0,2 bar | |||
Hysteresis | 1 °C | |||
Fan capacity (m³/h) app. | 2x 2,390 | 2x 3,390 | 2x 2,390 | 2x 3,100 |
Ventilation slot front (mm) app. | 370 x 630 | 360 x 620 | 410 x 640 | 430 x 880 |
Ventilation slot back (mm) app. | 360 x 630 | 380 x620 | 410 x 640 | 460 x 870 |
Housing material | X5CrNiMo 17-12-2 (V4A Stahl) / corrosion-resistant steel (V4A) |